Micromax Technology supply solar kits that are designed to provide power when required all year round. These kits can include a battery controller/charger for your battery with 12/24V auto-select, short circuit and overload protections and many other features. Automatic temperature compensation of the charge. . We are proud to be offering high quality battery chargers manufactured by market leaders Mean Well and AdelSystem. These companies strive to provide energy saving solutions for the ever changing and modern battery charging. [pdf]

Lithium battery charging cabinets are designed to safely store and charge lithium-ion batteries, minimizing risks such as fires and leaks.These cabinets help prevent accidents by containing potential battery fires and ensuring safe charging practices2.For example, Justrite’s cabinets feature a proprietary ChargeGuard™ system that reduces risks associated with thermal runaway and fire4.Asecos ION-LINE cabinets offer certified fire protection with a 90-minute fire resistance rating, ensuring safety during storage and charging5.Using a dedicated charging cabinet is essential for maintaining safety when working with lithium batteries. [pdf]
Justrite’s Lithium-Ion battery Charging Safety Cabinet is engineered to charge and store lithium batteries safely. Made with a proprietary 9-layer ChargeGuard™ system that helps minimize potential losses from fire, smoke, and explosions caused by Lithium batteries. Shop Now
Various cabinet sizes and equipment variants are available for the safe storage of lithium-ion batteries. There are safety cabinets that are used exclusively for the passive storage of batteries, as well as those that allow both the storage and charging of lithium-ion batteries.
There are safety cabinets that are used exclusively for the passive storage of batteries, as well as those that allow both the storage and charging of lithium-ion batteries. ION-LINE passive storage safety cabinets offer a standard 90-minute fire resistance rating both from the outside to the inside and vice versa.
This unit acts as a mobile charging hub for Li-ion batteries used in modern power tools, and as it is weatherproof, can be used indoors or outdoors. Lithium-Ion Battery Charging Cabinet (600 mm wide) with smoke detector for the active storage of lithium-ion batteries with 7 metal locker compartments.
These cabinets effectively prevent a fire from spreading from the outside to the batteries stored inside. At the same time, the risk of a fire inside the cabinet caused by the lithium-ion batteries or accumulators is also minimised because spread to the surrounding area is prevented.
Hazardous material cabinet for the active storage of lithium-ion batteries, offers fire protection from inside and has a sophisticated, 3 level fire warning/ suppression / system. Under bench cabinet with drawer for safe and secure charging of lithium batteries, with cylinder locking and locking state indicator.

In any electric motor application, the target equipment performance dictates the required motor power. The rated power of the motor is calculated from the combination of speed, torque, and duty cycle of the application that in turn establishes the critical voltage, current, and capacity requirements of the battery.. . One motor parameter that affects the performance of battery-powered applications is efficiency. Maximizing motor efficiency helps minimize required power capacity — in turn. . One essential criterion in battery selection is ensuring the battery will satisfy the motor’s voltage and current requirements when fully charged as well as continue to meet those requirements. [pdf]
Battery-powered motor applications need careful design work to match motor performance and power-consumption profiles to the battery type. Optimal motor and battery pairing relies on the selection of an efficient motor as well as a battery with the appropriate capacity, cost, size, maintainability, and discharge duration and curve.
One key motor performance parameter to consider in a battery-powered application is efficiency. Maximizing motor efficiency helps minimize the required power capacity and hence the size and cost of the battery solution. For this reason, brushless DC (BLDC) motors are preferred over brushed DC motors but are typically higher in price.
Generally, for a higher-power motor, a higher voltage is preferable. The selection of battery parameters is based on the range required for the vehicle and the capacity to provide peak discharge current and the duration for the peak current. Battery capacity (Ah or KWh) = (Mileage Requirement / Avg speed) x Avg current or power consumption.
Matching your motor voltage and your battery voltage cannot be understated if you want your setup to even work, let alone cause serious damage. If your motor is rated at 36v, get a 36v battery and so on. Getting a 72v battery and a 48v motor will likely fry your electronics located in the motors controller.
If your motor is rated at 36v, get a 36v battery and so on. Getting a 72v battery and a 48v motor will likely fry your electronics located in the motors controller. Using too low of a voltage will not give enough voltage to even register in the controller and you will not be able to power it up.
Optimal motor and battery pairing relies on the selection of an efficient motor as well as a battery with the appropriate capacity, cost, size, maintainability, and discharge duration and curve. Battery-powered AGVs for automated warehousing require brushless dc motors engineered for top efficiency.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.